Construction site enclosure spray series
2018-10-18 09:38 Tel:0086 18237122158

Construction site enclosure spray series
First, the introduction of the spray system

As the smog in many cities becomes more and more serious, the environment is getting more and more concerned by relevant departments. All kinds of construction sites, coal yards, quarries, concrete mixing stations, landfills that intensify dust pollution are required. At the yard, the sprinkler system needs to be installed on the enclosure of the waste recycling station to carry out water mist and dust reduction. The spray system mainly includes site spray dust reduction, concrete spray humidification, fire spray, garden spray, outdoor spray cooling, plant humidification and cooling.

Second, the composition of the spray system

         The spray system mainly consists of PPR water pipes, straight through, three-way, elbow and other water circulation pipes. The water tank provides the spray water source, the multi-stage pump gives the power to transmit, and the intelligent controller controls the whole system.
1. Intelligent controller: It adopts digital chip control to integrate upper and lower liquid level and pressure automatic control; it has three working modes: automatic, manual and remote control; it has overload, no load, lack of phase, ultra low pressure, etc. Protection function; with no-load restart function, time adjustable from 1 to 240 minutes; with fault memory function, the last 5 fault causes can be consulted; easy to install, easy to debug.
2. Multi-stage pump: Fill the pump with water before starting; open the water outlet valve to reduce the starting load of the motor and avoid burning the motor when starting. When the pump pressure is reduced, can reduce the number of pads between the pump body and the pump cover. If the pressure is too high, the motor will burn out.
3. Water tank: The water tank is equipped with automatic water level control valve. When the water level in the water tank is insufficient, the switch will automatically replenish the water source; when the water level reaches a certain height, the control valve will automatically close and stop the water supply.

Third, product features

1. Using digital chip control, integrating upper and lower liquid level and pressure automatic control
2. Available in automatic or manual mode
3. With overload, no load, phase loss, ultra low voltage and other protection functions
4. With no-load restart function, time adjustable from 1 to 240 minutes
5. With fault memory function, can check for the past 5 times fault causes.
6. Easy to install and easy to debug
As the smog in many cities becomes more and more serious, the environment is getting more and more concerned by relevant departments. All kinds of construction sites, coal yards, quarries, concrete mixing stations, landfills that intensify dust pollution are required. At the yard, the sprinkler system needs to be installed on the enclosure of the waste recycling station to carry out water mist and dust reduction. The spray system mainly includes site spray dust reduction, concrete spray humidification, fire spray, garden spray, outdoor spray cooling, plant humidification and cooling.

Fourth, equipment parameters

Flow rate: 6m3/h
Head: 160m
Power: 7.5kw
RPM: 2900r/min
Frequency: 50Hz
Voltage: 380V
Current: 15A

Fifth, the installation environment requirements

Operating temperature: -10 ° C to 40 ° C
Humidity: relative humidity is not more than 90%
Altitude: no more than 2000 meters
Probe line temperature resistance: 105 ° C

Sixth, the construction sequence

1. Pipe laying: The main switch of the waterway is set at the starting point. The main pipe is set to 4 meters. It is necessary to connect the water pipes at both ends with a three-way. Insert a spray pipe at the top and a straight through at the top to connect the nozzle with the pipe. (The distance between the spray tubes can be set according to actual needs) The water pipes are fixed on the enclosure by snaps and screws.
2. Pump installation: Firstly, fix the pump to the bracket with screws, wait for the wires to be connected, cover the water pump with the shelter, and fix it on the bracket with screws. After the water pump connector is wound around the raw ribbon, the water pipe is fastened to the water pump connector with a screw. The other end of the pump and pipe joints also needs to be tied with a raw ribbon and connected to the pipe.
3. The intelligent controller has a good waterproof setting and can be fixed only on the enclosure. The internal connection of the controller is complete, just connect the power cord, the remote control device line, the water level warning line, and the pump power line.
4. Connect the various controllers to each other and put them into operation.

Seven, installation precautions

1. Pump: A. Fill the pump with water before starting!
B. Open the water outlet valve first when starting to reduce the starting load of the motor and avoid burning the motor!
2. Controller: A. Fix the controller, fix it on the wall, open the junction box, and connect the power supply and pump according to the label!
B. According to the requirements, follow the diagram on the instruction manual to connect the line. When wiring, pay attention to the probe wire can not be short-circuited, can not lie on the pool wall; when extending the signal line (recommended to extend the cross-sectional area of the signal line is not more than 0.75mm²), please complete the package with waterproof tape!

Eight, use precautions

1. Starting up: After connecting all the lines, close the air switch, press the start button after selecting the working mode, the pump will start. Please pay attention to prevent electric shock!
2. The controller selects three working modes: automatic, manual and remote: A. In the automatic mode, if the start button is not pressed, the automatic mode light will flash and the controller will not run automatically. Only when the start button is pressed and the auto mode light is on, the controller can run automatically. B. Press the start or stop button in manual mode, the controller will start and stop the motor. In the manual mode, this control only protects against overload and phase loss, and is not controlled by water level or pressure, is not protected by no load.
3. Phase loss protection: If any phase of the load three-phase power supply is suddenly phased, the protector will cut off the pump power supply within 3 seconds.
4. Ultra-low voltage protection: When the grid voltage is lower than 300V, the controller will cut off the pump power supply within 20 seconds. The phenomenon is that the voltage and current meters display the same value, and the lack of phase indicator lights.
5. Overload protection: The controller has anti-time limit overload protection characteristics, that is, the more the overload current exceeds the set value, the faster the overload action protection speed.

Nine, disassembly considerations

1. When needs transitions to use, please disassemble the pipe and note that each interface cannot be forcibly pulled open, otherwise the pipe will be damaged and the interface will be broken!
2. The line removal of the intelligent controller should be careful, otherwise the line will be confused and cannot be used again. Please take care when moving the control box, don't throw it!

Platform management control system

The management personnel can download the environmental monitoring and control cloud platform through the computer or mobile phone, and remotely control the dust-reducing equipment such as the surrounding spray, tower crane spray, and fog gun machine to open and close the dust-free equipment without going to the construction site